SJE PumpMaster® Plus

International Version

pump master float switch

Pump switches provide automatic pump control.

The SJE PumpMaster® Plus pump switch is designed to directly control pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC in water and sewage applications.

The SJE PumpMaster® Plus pump switch is not sensitive to rotation or turbulence, allowing it to be used in both calm and turbulent applications.

pump master float switch

Features

  • Flexible SJOW, water-resistant (CPE) cable
  • High impact, corrosion resistant, PVC float housing
  • Temperature rating up to 60º C (140º F)
  • Maximum water depth of 14 meters (46 feet) or 138 kPa (20 psi)
  • IPX8 enclosure rating
  • Float dimensions: 7.75 cm diameter x 9.04 cm long (3.05 inch x 3.56 inch)
  • Adjustable pumping range of 18 to 91 cm (7 to 36 inches)
  • Heavy-duty contacts
  • UL Recognized, CSA certified
Note: These switches must be used with pumps that provide integral thermal overload protection.

PumpSwitch On/Off Diagram

Options:
  • For pump up or pump down applications as specified by part number
  • With a 120 VAC or 230 VAC piggy-back plug
  • Without a plug for direct wiring in 120 VAC or 230 VAC applications
  • In standard cable lengths of 10, 15, 20, or 30 feet (3, 5, 6, or 10 meters) – longer lengths available
UL Recognized, CSA Certified
Five-Year Limited Warranty

Specifications

CABLE:
  • Flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE)
FLOAT:
  • 7.75 cm diameter x 9.04 cm long (3.05 in x 3.56 in) high impact, corrosion resistance, PVC housing for use in sewage and water up to 60°C (140°F)
ELECTRICAL:
  • 120 VAC 50/60 Hz Single Phase:
    • Maximum Pump Running Current: 15 amps
    • Maximum Pump Starting Current: 85 amps
    • Recommended Pump HP: 3/4 HP or less
  • 230 VAC 50/60 Hz Single Phase:
    • Maximum Pump Running Current: 15 amps
    • Maximum Pump Starting Current: 85 amps
    • Recommended Pump HP: 2 HP or less

NOTE: This switch must be used with pumps that provide integral thermal overload protection.